Euterpe Single-Use-Pump's (SUP) all consist of:
The Euterpe Air-Operated-Diaphragm-Positive-Displacement (AODPD) Single-Use-Pump (SUP) cell’s consist of a housing integrating a valve body, a dome, the diaphragm, and the fluid conveying hoses – all supplied pre-sterilized in dual film bags.
Stand-alone product, model names |
Euterpe-30 |
Euterpe-100 |
Euterpe-300 |
Euterpe-500 |
Layout, number of diaphragms |
single |
single |
single |
single |
Diaphragm diameter, mm |
60 | 80 | 125 | 150 |
Diaphragm stroke, mm |
25 | 39 | 46 | 54 |
Stroke Volume, SV, mL / 100 % stroke |
30 |
100 |
300 |
500 |
Cardiac Output, CO range, mL / min |
0 - 750 |
0 - 1,000 |
0 - 3,000 |
0 - 5,000 |
Beats-per-Minute, BpM |
0 - 30 |
0 - 20 |
0 - 15 |
0 - 14 |
Typical hose connection, ID/OD mm |
4/8 |
8/12 |
12/18 |
12/18 |
SUP cell weight, grams | 100 | 200 | 300 | 400 |
The basics in operation is copied from the human heart functionality:
- Cardiac Output (CO) = total pumped volume, SUP capacity, ml/min (CO = BpM x SV)
- Beats-per-Minute (BpM) = ranging 0 - 30 BpM, SUP diameter/stroke/volume depending
- Stroke Volume (SV) = programmable from 10 - 100% of SUP cell specification





Physical features
- No expensive housing materials for traditional steam cleaning requirements
- No mechanical axle seals
- No mechanical rotating parts such as electrical motor, coupling or gears
- No moving ball valves, only passive cross-slit silicone valves
- All simple single-use plastic parts – contamination eliminated
- Low weight and compact design gives OEM manufactures new freedom to design equipment
- Measures accurately pumped volume, a true Positive Displacement pump – no in-line flow-sensor is needed
- All pumps offer infinite turn-down, turn-up scale of 1:5.000
Operating features
- Volumetric operation precision better than 1% - without any extra flow sensor
- Volume per stroke depending on pump size - no minimum volume exist
- Zero spallation / shedding of membrane materials - shear never introduced
- Self-priming from 2 meter suction height
- Standard fluid pressure 1 bar - higher pressure like 3-5 Bar require customized body
- No need for calibration - build in artificial inteligence in Drive Unit
- Pump any fluid - any mixture of liquid and gases
- Dry running for extended periods
- Self-emptying, drain on inlet and purge on outlet as the pump will convey gas as well
- Single-use, disposable wetted parts eliminate cleaning issues – just un-pack and exchange without any tools needed
- Very gently operation with no rotating or rubbing parts - no shear introduced between used polymeric materials parts creating nano size polluting particles
- Working pressure as much as 5 Bar on special models makes the SUP suitable for connection with filtration devices
- Two or four pumps able to operate fully controlled and in parallel connected to Atropos-2
- Two pumps able to operate fully controlled in parallel when connected to Atropos-1
Programming features (on Atropos)
- Select the continuous volume you want to pump – (well, according to pump size)
- Select the total volume you want to pump
- Select the time you want the pump to operate
- Real-time information about pumping, pumped volume and velocity
Maintenance features
- No tools needed replacing the SUP cell - takes only one minute !
- No lubrication needed
- No need to strip down pump for cleaning
- Longevity - tested to last 1 million cycles at 75% CO
Installation features
- Single-Use-Pump cell may easily be part of an all sterile process package
- No tooling needed for Single-Use-Pump cell replacement - one minute operation
Data collection features of Atropos Drive Unit
- On-line operation pressure measured by build-in pressure sensor
- On-line Mass-Flow-Control / metering, the pump measures the volume pumped with better than 1% accuracy - without external flow sensors!
- Data acquisition, data logging
Communication features of Atropos drive unit
- Single-Use-Pump cell's need connection to Atropos Drive Unit (requires only pressurized air, vacuum and 24 VDC electrical power)
- TCP/IP bus connection or Wi-Fi connection
- All Euterpe kids are stand-alone and share the same family of Atropos Drive Unit's
- Atropos software up-gradable
- Atropos units facilitate a webhost, which allow the user to access Atropos via Wi-Fi as well as via IP/TCP from many devices via Ethernet, USB connection (for data export), OPC communication
- Access Atropos via build-in touch sensitive display or connect via Wi-Fi a PAD, Smartphone or PC
Not designed for:
- Viscosity higher than 10,000 centiStoke
- Very abrasive materials for a long time